Configuration on Headless Systems

If you are running Tonido on a system without display, you will need to follow the steps below to setup Tonido correctly. First, you will have to change a config setting to create a profile remotely.

Do the following:

  1. Start Tonido first to let it initialize the config data. Stop Tonido.
  2. Navigate to the following location: ~/tonido/data
  3. Open the configex.xml file
  4. Change the following values

    <rowentry>
     <name>WebAccess</name>
     <type>string</type>
     <value>local</value>
    </rowentry>
    <rowentry>
     <name>RemoteAdmin</name>
     <type>bool</type>
     <value>0</value>
    </rowentry>

    To

    <rowentry>
     <name>WebAccess</name>
     <type>string</type>
     <value>all</value>
    </rowentry>
    <rowentry>
     <name>RemoteAdmin</name>
     <type>bool</type>
     <value>1</value>
    </rowentry>
     

     

     

  5.  Restart Tonido 
  6. Open your browser and navigate to http://<serverip>:10001

 

 

 

 

 

 

 

 